↓ Skip to main content

Dove Medical Press

A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer

Overview of attention for article published in Research and Reports in Urology, August 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age

Mentioned by

twitter
3 X users
facebook
1 Facebook page

Citations

dimensions_citation
24 Dimensions

Readers on

mendeley
58 Mendeley
Title
A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer
Published in
Research and Reports in Urology, August 2016
DOI 10.2147/rru.s58262
Pubmed ID
Authors

Vladimir Avkshtol, Yanqun Dong, Shelly B Hayes, Mark A Hallman, Robert A Price, Mark L Sobczak, Eric M Horwitz, Nicholas G Zaorsky

Abstract

Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (<6% grade 3-4 late toxicities). Other outcomes (eg, overall and cancer-specific mortality) cannot be compared, given the indolent course of low-risk prostate cancer. At this time, neither SBRT device is recommended over the other for all patients; however, gantry-based SBRT machines have the abilities of treating larger volumes with conventional fractionation, shorter treatment time per fraction (~15 minutes for gantry vs ~45 minutes for robotic arm), and the ability to achieve better plans among obese patients (since they are able to use energies >6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

X Demographics

X Demographics

The data shown below were collected from the profiles of 3 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 58 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Spain 1 2%
Unknown 57 98%

Demographic breakdown

Readers by professional status Count As %
Student > Master 10 17%
Other 8 14%
Researcher 6 10%
Student > Postgraduate 6 10%
Student > Doctoral Student 5 9%
Other 15 26%
Unknown 8 14%
Readers by discipline Count As %
Medicine and Dentistry 29 50%
Physics and Astronomy 7 12%
Engineering 4 7%
Pharmacology, Toxicology and Pharmaceutical Science 2 3%
Business, Management and Accounting 1 2%
Other 4 7%
Unknown 11 19%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 09 April 2018.
All research outputs
#13,401,501
of 22,883,326 outputs
Outputs from Research and Reports in Urology
#96
of 224 outputs
Outputs of similar age
#199,056
of 366,370 outputs
Outputs of similar age from Research and Reports in Urology
#5
of 6 outputs
Altmetric has tracked 22,883,326 research outputs across all sources so far. This one is in the 41st percentile – i.e., 41% of other outputs scored the same or lower than it.
So far Altmetric has tracked 224 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 9.0. This one has gotten more attention than average, scoring higher than 57% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 366,370 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 45th percentile – i.e., 45% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 6 others from the same source and published within six weeks on either side of this one.