↓ Skip to main content

Dove Medical Press

Comparative analysis of the performance of two different platforms for femtosecond laser-assisted cataract surgery

Overview of attention for article published in Clinical Ophthalmology, October 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
2 X users

Citations

dimensions_citation
16 Dimensions

Readers on

mendeley
33 Mendeley
Title
Comparative analysis of the performance of two different platforms for femtosecond laser-assisted cataract surgery
Published in
Clinical Ophthalmology, October 2016
DOI 10.2147/opth.s115483
Pubmed ID
Authors

Robert P Rivera, Phillip C Hoopes, Steven H Linn, Phillip C Hoopes

Abstract

To analyze and compare the intraoperative and postoperative outcomes of cataract surgery performed with two different femtosecond laser platforms. Randomized controlled prospective intraindividual comparative study including 90 eyes of 45 patients aged between 61 and 86 years. All eyes underwent bilateral cataract surgery assisted with femtosecond laser technology. Eyes were randomized to one of two different femtosecond laser platforms: Catalys Precision system (Abbott Medical Optics Inc., Santa Ana, CA, USA) (Catalys group), and LenSx system (Alcon-LenSx Inc., Aliso Viejo, CA, USA) (LenSx group). Several intraoperative parameters and changes in corrected distance visual acuity and corneal endothelial density were evaluated and compared. The LenSx group showed a significantly higher cumulative dissipated energy and phacoemulsification power needed compared to the Catalys group (P≤0.043). Likewise, a longer patient interface preparation time, more severe perception of pressure by patient, and more cases of subconjunctival hemorrhage were found in the LenSx group (P≤0.014). A complete capsulotomy was achieved in more cases in the Catalys group compared to the LenSx group (P=0.002). Regarding corneal incisions, no statistically significant differences were found between groups (P≥0.071). The same occurred for postoperative corrected distance visual acuity (P≥0.48), endothelial cell density changes (P≥0.14), and the incidence of corneal edema or flare (P≥0.399). Cataract surgery with the two evaluated femtosecond laser platforms is a safe procedure, with reduced phaco time and energy, and preservation of corneal endothelium integrity. However, both systems differ in the performance of capsulotomy and the procedure of docking, with an advantage of the Catalys over the LenSx system.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 33 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 33 100%

Demographic breakdown

Readers by professional status Count As %
Other 7 21%
Researcher 3 9%
Student > Postgraduate 3 9%
Student > Bachelor 2 6%
Student > Master 2 6%
Other 4 12%
Unknown 12 36%
Readers by discipline Count As %
Medicine and Dentistry 17 52%
Pharmacology, Toxicology and Pharmaceutical Science 1 3%
Immunology and Microbiology 1 3%
Nursing and Health Professions 1 3%
Sports and Recreations 1 3%
Other 1 3%
Unknown 11 33%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 02 November 2016.
All research outputs
#17,286,645
of 25,374,917 outputs
Outputs from Clinical Ophthalmology
#1,803
of 3,714 outputs
Outputs of similar age
#216,526
of 332,577 outputs
Outputs of similar age from Clinical Ophthalmology
#31
of 72 outputs
Altmetric has tracked 25,374,917 research outputs across all sources so far. This one is in the 21st percentile – i.e., 21% of other outputs scored the same or lower than it.
So far Altmetric has tracked 3,714 research outputs from this source. They receive a mean Attention Score of 4.9. This one is in the 33rd percentile – i.e., 33% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 332,577 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 26th percentile – i.e., 26% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 72 others from the same source and published within six weeks on either side of this one. This one is in the 40th percentile – i.e., 40% of its contemporaries scored the same or lower than it.