↓ Skip to main content

Dove Medical Press

Design evolution enhances patient compliance for low-intensity pulsed ultrasound device usage

Overview of attention for article published in Medical Devices : Evidence and Research, November 2016
Altmetric Badge

About this Attention Score

  • In the top 5% of all research outputs scored by Altmetric
  • Among the highest-scoring outputs from this source (#12 of 314)
  • High Attention Score compared to outputs of the same age (95th percentile)
  • High Attention Score compared to outputs of the same age and source (88th percentile)

Mentioned by

news
7 news outlets
twitter
1 X user

Citations

dimensions_citation
6 Dimensions

Readers on

mendeley
12 Mendeley
Title
Design evolution enhances patient compliance for low-intensity pulsed ultrasound device usage
Published in
Medical Devices : Evidence and Research, November 2016
DOI 10.2147/mder.s119887
Pubmed ID
Authors

Neill M Pounder, John T Jones, Kevin J Tanis

Abstract

Poor patient compliance or nonadherence with prescribed treatments can have a significant unfavorable impact on medical costs and clinical outcomes. In the current study, voice-of-the-customer research was conducted to aid in the development of a next-generation low-intensity pulsed ultrasound (LIPUS) bone healing product. An opportunity to improve patient compliance reporting was identified, resulting in the incorporation into the next-generation device of a visual calendar that provides direct feedback to the patient, indicating days for which they successfully completed treatment. Further investigation was done on whether inclusion of the visual calendar improved patient adherence to the prescribed therapy (20 minutes of daily treatment) over a 6-month period. Thus, 12,984 data files were analyzed from patients prescribed either the earlier- or the next-generation LIPUS device. Over the 6-month period, overall patient compliance was 83.8% with the next-generation LIPUS device, compared with 74.2% for the previous version (p<0.0001). Incorporation of the calendar feature resulted in compliance never decreasing below 76% over the analysis period, whereas compliance with the earlier-generation product fell to 51%. A literature review on the LIPUS device shows a correlation between clinical effectiveness and compliance rates more than 70%. Incorporation of stakeholder feedback throughout the design and innovation process of a next-generation LIPUS device resulted in a measurable improvement in patient adherence, which may help to optimize clinical outcomes.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 12 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 12 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 3 25%
Other 2 17%
Student > Ph. D. Student 2 17%
Student > Doctoral Student 1 8%
Professor 1 8%
Other 2 17%
Unknown 1 8%
Readers by discipline Count As %
Medicine and Dentistry 5 42%
Nursing and Health Professions 1 8%
Pharmacology, Toxicology and Pharmaceutical Science 1 8%
Economics, Econometrics and Finance 1 8%
Engineering 1 8%
Other 0 0%
Unknown 3 25%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 54. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 05 December 2016.
All research outputs
#779,288
of 25,457,297 outputs
Outputs from Medical Devices : Evidence and Research
#12
of 314 outputs
Outputs of similar age
#14,855
of 318,028 outputs
Outputs of similar age from Medical Devices : Evidence and Research
#1
of 9 outputs
Altmetric has tracked 25,457,297 research outputs across all sources so far. Compared to these this one has done particularly well and is in the 96th percentile: it's in the top 5% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 314 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 12.3. This one has done particularly well, scoring higher than 96% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 318,028 tracked outputs that were published within six weeks on either side of this one in any source. This one has done particularly well, scoring higher than 95% of its contemporaries.
We're also able to compare this research output to 9 others from the same source and published within six weeks on either side of this one. This one has scored higher than all of them