↓ Skip to main content

Dove Medical Press

Future developments in biliary stenting

Overview of attention for article published in Clinical and Experimental Gastroenterology, June 2013
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (80th percentile)
  • Good Attention Score compared to outputs of the same age and source (72nd percentile)

Mentioned by

patent
1 patent
wikipedia
1 Wikipedia page
googleplus
1 Google+ user

Citations

dimensions_citation
13 Dimensions

Readers on

mendeley
14 Mendeley
Title
Future developments in biliary stenting
Published in
Clinical and Experimental Gastroenterology, June 2013
DOI 10.2147/ceg.s34435
Pubmed ID
Authors

Clark D Hair, Divyesh V Sejpal

Abstract

Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 14 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
China 1 7%
Unknown 13 93%

Demographic breakdown

Readers by professional status Count As %
Researcher 5 36%
Student > Ph. D. Student 2 14%
Professor > Associate Professor 2 14%
Student > Master 1 7%
Other 1 7%
Other 2 14%
Unknown 1 7%
Readers by discipline Count As %
Medicine and Dentistry 11 79%
Engineering 2 14%
Unknown 1 7%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 7. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 19 March 2020.
All research outputs
#4,155,790
of 22,715,151 outputs
Outputs from Clinical and Experimental Gastroenterology
#62
of 306 outputs
Outputs of similar age
#35,795
of 194,195 outputs
Outputs of similar age from Clinical and Experimental Gastroenterology
#3
of 11 outputs
Altmetric has tracked 22,715,151 research outputs across all sources so far. Compared to these this one has done well and is in the 80th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 306 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 8.6. This one has done well, scoring higher than 79% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 194,195 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 80% of its contemporaries.
We're also able to compare this research output to 11 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 72% of its contemporaries.