↓ Skip to main content

Dove Medical Press

The 24-hour intraocular pressure control by tafluprost/timolol fixed combination after switching from the concomitant use of tafluprost and timolol gel-forming solution, in patients with primary open-a…

Overview of attention for article published in Clinical Ophthalmology, February 2018
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
6 Dimensions

Readers on

mendeley
11 Mendeley
Title
The 24-hour intraocular pressure control by tafluprost/timolol fixed combination after switching from the concomitant use of tafluprost and timolol gel-forming solution, in patients with primary open-angle glaucoma
Published in
Clinical Ophthalmology, February 2018
DOI 10.2147/opth.s152507
Pubmed ID
Authors

Kenji Nakamoto, Masahiko Takeshi, Toshihiko Hiraoka, Mayuko Eguchi, Yuichiro Nakano, Naomi Otsuka, Hiroko Hizaki, Hiromi Akai, Masayo Hashimoto

Abstract

The aim of this study was to evaluate the 24-hour intraocular pressure (IOP)-control effect of the tafluprost/timolol fixed combination (TAF/TIM-FC) in patients with primary open-angle glaucoma after they switched from the concomitant use of tafluprost and timolol gel-forming solution. Twenty patients with primary open-angle glaucoma (12 male and 8 female; mean ± SD age, 57.0±7.1 years) were included in this study. The patients were treated for 8 weeks with the concomitant administration of tafluprost and timolol gel-forming solution (evening dosing). At the end of this period, the patients underwent 24-hour IOP monitoring (measured at 21:00, 01:00, 05:00, 09:00, 13:00 and 17:00). IOP was measured with Goldmann applanation tonometer (GAT) and Icare PRO at sitting position at all timepoints and additionally, at supine position with Icare PRO tonometer at 01:00 and 05:00. The patients were then all switched to TAF/TIM-FC treatment (evening dosing). After 8 weeks, the 24-hour IOP monitoring was repeated. Nineteen patients completed the study. The mean 24-hour IOPs in the concomitant and TAF/TIM-FC phases were 13.8±2.7 vs 13.3±2.8 mmHg (P=0.0033) with the GAT in the sitting position and 13.96±2.56 vs 13.48±2.56 mmHg (P=0.0120) with the Icare PRO in habitual positions. In comparison with the concomitant phase, significantly lower IOP was observed for the TAF/TIM-FC phase at 21:00 and 01:00 with the GAT and at 01:00 with the Icare PRO. In addition, the maximum IOP and fluctuations in IOP in habitual positions were lower for the TAF/TIM-FC phase than for the concomitant phase. TAF/TIM-FC showed a stable 24-hour IOP-lowering effect and was equally or more effective than the concomitant use of tafluprost and timolol gel, both when sitting and when in habitual positions.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 11 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 11 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 1 9%
Lecturer > Senior Lecturer 1 9%
Librarian 1 9%
Other 1 9%
Professor 1 9%
Other 2 18%
Unknown 4 36%
Readers by discipline Count As %
Medicine and Dentistry 3 27%
Environmental Science 1 9%
Business, Management and Accounting 1 9%
Pharmacology, Toxicology and Pharmaceutical Science 1 9%
Computer Science 1 9%
Other 1 9%
Unknown 3 27%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 March 2018.
All research outputs
#22,767,715
of 25,382,440 outputs
Outputs from Clinical Ophthalmology
#3,207
of 3,714 outputs
Outputs of similar age
#389,450
of 448,849 outputs
Outputs of similar age from Clinical Ophthalmology
#32
of 34 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 3,714 research outputs from this source. They receive a mean Attention Score of 4.9. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 448,849 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 34 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.