↓ Skip to main content

Dove Medical Press

Measuring oxygen levels in Caco-2 cultures

Overview of attention for article published in Hypoxia, October 2015
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (83rd percentile)
  • High Attention Score compared to outputs of the same age and source (80th percentile)

Mentioned by

news
1 news outlet
twitter
1 X user
facebook
1 Facebook page

Citations

dimensions_citation
25 Dimensions

Readers on

mendeley
63 Mendeley
Title
Measuring oxygen levels in Caco-2 cultures
Published in
Hypoxia, October 2015
DOI 10.2147/hp.s85625
Pubmed ID
Authors

Nathalie E Zeitouni, Joachim Fandrey, Hassan Y Naim, Maren von Köckritz-Blickwede

Abstract

Measuring oxygen levels in three different systems of Caco-2 cell culture. Caco-2 cells were cultured in three different systems, using conventional polystyrene 24-well plates, special 24-well gas permeable plates, or on membrane inserts in conventional plates. Optical sensor spots were used to measure dissolved O2 levels in these cultured cells over the course of 6 days under normoxia (143 mmHg) and for 6 hours under hypoxia (7 mmHg). Western blot analysis was used to determine the protein levels of hypoxia-inducible factor 1α (HIF-1α) in the different cultures. All culture systems displayed lower O2 levels over time than expected when cultured under normoxia conditions. On average, O2 levels reached as low as 25 mmHg in 24-well plates but remained at 97 and 117 mmHg in gas permeable plates and membrane inserts, respectively. Under hypoxia, 1 mL cell cultures equilibrated to 7 mmHg O2 within the first 60 minutes and dropped to 0.39 and 0.61 mmHg O2 in 24-well and gas permeable plates, respectively, after the 6-hour incubation period. Cultures in membrane inserts did not equilibrate to 7 mmHg by the end of the 6-hour incubation period, where the lowest O2 measurements reached 23.12 mmHg. Western blots of HIF-1α protein level in the whole cell lysates of the different Caco-2 cultures revealed distinct stabilization of HIF-1α after hypoxic incubation for 1, 2, and 4 hours in 24-well plates as well as gas permeable plates. For membrane inserts, notable HIF-1α was seen after 4 hours of hypoxic incubation. Cellular oxygen depletion was achieved in different hypoxic Caco-2 culture systems. However, different oxygen levels comparing different culture systems indicate that O2 level should be carefully considered in oxygen-dependent experiments.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 63 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 63 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 20 32%
Researcher 10 16%
Student > Master 7 11%
Student > Bachelor 5 8%
Student > Doctoral Student 2 3%
Other 6 10%
Unknown 13 21%
Readers by discipline Count As %
Agricultural and Biological Sciences 15 24%
Biochemistry, Genetics and Molecular Biology 9 14%
Medicine and Dentistry 6 10%
Pharmacology, Toxicology and Pharmaceutical Science 5 8%
Immunology and Microbiology 4 6%
Other 8 13%
Unknown 16 25%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 10. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 22 May 2019.
All research outputs
#3,069,253
of 22,830,751 outputs
Outputs from Hypoxia
#4
of 48 outputs
Outputs of similar age
#43,666
of 274,926 outputs
Outputs of similar age from Hypoxia
#1
of 5 outputs
Altmetric has tracked 22,830,751 research outputs across all sources so far. Compared to these this one has done well and is in the 86th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 48 research outputs from this source. They receive a mean Attention Score of 3.1. This one scored the same or higher as 44 of them.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 274,926 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 83% of its contemporaries.
We're also able to compare this research output to 5 others from the same source and published within six weeks on either side of this one. This one has scored higher than all of them