Magnetic resonance imaging investigation of the bone conduction implant – a pilot study at 1.5 Tesla

Overview of attention for article published in Medical Devices : Evidence and Research, October 2015
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age

Mentioned by

twitter
2 X users
facebook
1 Facebook page

Citations

dimensions_citation
17 Dimensions

Readers on

mendeley
29 Mendeley
Title
Magnetic resonance imaging investigation of the bone conduction implant – a pilot study at 1.5 Tesla
Published in
Medical Devices : Evidence and Research, October 2015
DOI 10.2147/mder.s90704
Pubmed ID
Authors

Karl-Johan Fredén Jansson, Bo Håkansson, Sabine Reinfeldt, Cristina Rigato, Måns Eeg-Olofsson

Abstract

The objective of this pilot study was to investigate if an active bone conduction implant (BCI) used in an ongoing clinical study withstands magnetic resonance imaging (MRI) of 1.5 Tesla. In particular, the MRI effects on maximum power output (MPO), total harmonic distortion (THD), and demagnetization were investigated. Implant activation and image artifacts were also evaluated. One implant was placed on the head of a test person at the position corresponding to the normal position of an implanted BCI and applied with a static pressure using a bandage and scanned in a 1.5 Tesla MRI camera. Scanning was performed both with and without the implant, in three orthogonal planes, and for one spin-echo and one gradient-echo pulse sequence. Implant functionality was verified in-between the scans using an audio processor programmed to generate a sequence of tones when attached to the implant. Objective verification was also carried out by measuring MPO and THD on a skull simulator as well as retention force, before and after MRI. It was found that the exposure of 1.5 Tesla MRI only had a minor effect on the MPO, ie, it decreased over all frequencies with an average of 1.1±2.1 dB. The THD remained unchanged above 300 Hz and was increased only at lower frequencies. The retention magnet was demagnetized by 5%. The maximum image artifacts reached a distance of 9 and 10 cm from the implant in the coronal plane for the spin-echo and the gradient-echo sequence, respectively. The test person reported no MRI induced sound from the implant. This pilot study indicates that the present BCI may withstand 1.5 Tesla MRI with only minor effects on its performance. No MRI induced sound was reported, but the head image was highly distorted near the implant.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 29 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 29 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 5 17%
Student > Master 3 10%
Researcher 3 10%
Student > Bachelor 3 10%
Other 2 7%
Other 5 17%
Unknown 8 28%
Readers by discipline Count As %
Medicine and Dentistry 9 31%
Engineering 4 14%
Psychology 2 7%
Nursing and Health Professions 1 3%
Social Sciences 1 3%
Other 3 10%
Unknown 9 31%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 February 2016.
All research outputs
#17,439,813
of 25,584,565 outputs
Outputs from Medical Devices : Evidence and Research
#190
of 303 outputs
Outputs of similar age
#172,175
of 287,342 outputs
Outputs of similar age from Medical Devices : Evidence and Research
#8
of 12 outputs
Altmetric has tracked 25,584,565 research outputs across all sources so far. This one is in the 21st percentile – i.e., 21% of other outputs scored the same or lower than it.
So far Altmetric has tracked 303 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 12.7. This one is in the 26th percentile – i.e., 26% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 287,342 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 31st percentile – i.e., 31% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 12 others from the same source and published within six weeks on either side of this one. This one is in the 25th percentile – i.e., 25% of its contemporaries scored the same or lower than it.