Validation of pressure gradient and peripheral fractional flow reserve measured by a pressure wire for diagnosis of iliofemoral artery disease with intermediate stenosis

Overview of attention for article published in Medical Devices : Evidence and Research, November 2015
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
3 X users

Citations

dimensions_citation
9 Dimensions

Readers on

mendeley
30 Mendeley
Title
Validation of pressure gradient and peripheral fractional flow reserve measured by a pressure wire for diagnosis of iliofemoral artery disease with intermediate stenosis
Published in
Medical Devices : Evidence and Research, November 2015
DOI 10.2147/mder.s83768
Pubmed ID
Authors

Naotaka Murata, Hideaki Aihara, Yoshimitu Soga, Yusuke Tomoi, Seiichi Hiramori, Yohei Kobayashi, Kei Ichihashi, Nobuhiro Tanaka, Hiroyoshi Yokoi

Abstract

To examine the pressure gradient and peripheral fractional flow reserve (pFFR) measured by a pressure wire as indicators of hemodynamic significance in iliofemoral angiographic intermediate stenosis. The utility of pressure measurements using a pressure wire with vasodilators is unclear in cases with intermediate iliofemoral stenosis. The mean pressure gradient (MPG) and mean pressure ratio (MPR) were measured at baseline and after injection of isosorbide dinitrate in 23 lesions with angiographically intermediate iliofemoral stenosis. Patients with complex lesions, infrapopliteal artery lesions, chronic total occlusion, and surgical bypass grafts were excluded. Hyperemic MPR was considered equivalent to pFFR. Changes in parameters in response to vasodilators were assessed and correlations of peak systolic velocity ratio (PSVR) with hyperemic MPG and pFFR were examined using duplex ultrasound. After injection of isosorbide dinitrate, hyperemic MPG increased significantly (from 9.0±5.7 to 16.3±6.2 mmHg; P<0.05) and hyperemic MPR (pFFR) decreased significantly (from 0.92±0.06 to 0.81±0.07; P<0.05). PSVR was significantly correlated with hyperemic MPG (R=0.52; P<0.05) and pFFR (R=-0.50; P<0.05). The optimal cut-off value of pFFR as an indicator of significant hemodynamic stenosis (PSVR >2.5) was 0.85 (area under the curve 0.72; sensitivity 94%; specificity 50%, P<0.05). pFFR measured using a pressure wire is reliable for prediction of hemodynamic significance in iliofemoral intermediate stenosis.

X Demographics

X Demographics

The data shown below were collected from the profiles of 3 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 30 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United States 1 3%
Unknown 29 97%

Demographic breakdown

Readers by professional status Count As %
Student > Master 7 23%
Researcher 3 10%
Student > Ph. D. Student 3 10%
Student > Bachelor 2 7%
Other 2 7%
Other 3 10%
Unknown 10 33%
Readers by discipline Count As %
Medicine and Dentistry 15 50%
Engineering 2 7%
Nursing and Health Professions 1 3%
Biochemistry, Genetics and Molecular Biology 1 3%
Unknown 11 37%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 06 December 2015.
All research outputs
#15,799,182
of 25,457,858 outputs
Outputs from Medical Devices : Evidence and Research
#170
of 314 outputs
Outputs of similar age
#152,025
of 295,018 outputs
Outputs of similar age from Medical Devices : Evidence and Research
#6
of 11 outputs
Altmetric has tracked 25,457,858 research outputs across all sources so far. This one is in the 36th percentile – i.e., 36% of other outputs scored the same or lower than it.
So far Altmetric has tracked 314 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 12.3. This one is in the 45th percentile – i.e., 45% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 295,018 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 47th percentile – i.e., 47% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 11 others from the same source and published within six weeks on either side of this one. This one is in the 45th percentile – i.e., 45% of its contemporaries scored the same or lower than it.