↓ Skip to main content

Dove Medical Press

Astigmatism management in cataract surgery with Precizon® toric intraocular lens: a prospective study

Overview of attention for article published in Clinical Ophthalmology, January 2016
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (83rd percentile)
  • High Attention Score compared to outputs of the same age and source (80th percentile)

Mentioned by

twitter
10 X users

Citations

dimensions_citation
16 Dimensions

Readers on

mendeley
27 Mendeley
Title
Astigmatism management in cataract surgery with Precizon® toric intraocular lens: a prospective study
Published in
Clinical Ophthalmology, January 2016
DOI 10.2147/opth.s91298
Pubmed ID
Authors

Carolina Vale, Carlos Menezes, J Firmino-Machado, Pedro Rodrigues, Miguel Lume, Paula Tenedório, Pedro Menéres, Maria do Céu Brochado

Abstract

The purpose of this study was to evaluate the visual and refractive outcomes and rotational stability of the new aspheric Precizon(®) toric intraocular lens (IOL) for the correction of corneal astigmatism in cataract surgery. Department of Ophthalmology, Hospital Geral de Santo António - Centro Hospitalar do Porto, EPE and Hospital de Pedro Hispano, Matosinhos, Portugal. This was a prospective clinical study. A total of 40 eyes of 27 patients with corneal astigmatism greater than 1.0 diopter (D) underwent cataract surgery with implantation of Precizon(®) toric IOL. IOL power calculation was performed using optical coherence biometry (IOLMaster(®)). Outcomes of uncorrected (UDVA) and best-spectacle corrected distance visual acuities (BCDVA), refraction, and IOL rotation were analyzed at the 1st week, 1st, 3rd, and 6th month's evaluations. The median postoperative UDVA was better than preoperative best-spectacle corrected distance visual acuity (0.02 [0.06] logMAR vs 0.19 [0.20] logMAR, P<0.001). At 6 months, postoperative UDVA was 0.1 logMAR or better in 95% of the eyes. At last follow-up, the mean spherical equivalent was reduced from -3.35±3.10 D to -0.02±0.30 D (P<0.001) with 97.5% of the eyes within ±0.50 D of emmetropia. The mean preoperative keratometric cylinder was 2.34±0.95 D and the mean postoperative refractive cylinder was 0.24±0.27 D (P<0.001). The mean IOL rotation was 2.43°±1.55°. None of the IOLs required realignment. Precizon(®) toric IOL revealed very good rotational stability and performance regarding predictability, efficacy, and safety in the correction of preexisting regular corneal astigmatism associated with cataract surgery.

X Demographics

X Demographics

The data shown below were collected from the profiles of 10 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 27 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Nigeria 1 4%
Unknown 26 96%

Demographic breakdown

Readers by professional status Count As %
Researcher 7 26%
Student > Master 5 19%
Student > Postgraduate 3 11%
Other 2 7%
Student > Ph. D. Student 1 4%
Other 2 7%
Unknown 7 26%
Readers by discipline Count As %
Medicine and Dentistry 16 59%
Mathematics 1 4%
Immunology and Microbiology 1 4%
Computer Science 1 4%
Unknown 8 30%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 9. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 02 February 2018.
All research outputs
#4,300,739
of 25,373,627 outputs
Outputs from Clinical Ophthalmology
#374
of 3,712 outputs
Outputs of similar age
#67,518
of 399,674 outputs
Outputs of similar age from Clinical Ophthalmology
#11
of 57 outputs
Altmetric has tracked 25,373,627 research outputs across all sources so far. Compared to these this one has done well and is in the 83rd percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 3,712 research outputs from this source. They receive a mean Attention Score of 4.9. This one has done well, scoring higher than 89% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 399,674 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 83% of its contemporaries.
We're also able to compare this research output to 57 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 80% of its contemporaries.