↓ Skip to main content

Dove Medical Press

Feasibility of spirometry in primary care to screen for COPD: a pilot study

Overview of attention for article published in International Journal of Chronic Obstructive Pulmonary Disease, February 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
10 Dimensions

Readers on

mendeley
44 Mendeley
Title
Feasibility of spirometry in primary care to screen for COPD: a pilot study
Published in
International Journal of Chronic Obstructive Pulmonary Disease, February 2016
DOI 10.2147/copd.s96385
Pubmed ID
Authors

Violaine Giraud, Alain Beauchet, Thierry Gomis, Thierry Chinet

Abstract

COPD is a frequent but underdiagnosed disease whose diagnosis relies on the spirometric demonstration of bronchial obstruction. Spirometry use by general practitioners could represent the first line in COPD diagnosis. Because duration of spirometry is retarding its development in primary care, we decided to measure the time it requires in the primary-care context in France. Ten volunteer general practitioners were trained during two 3-hour theoretical and practical continuing education sessions. Then, from October 2013 to May 2014, they included patients without any known respiratory disease but at risk of developing COPD (age: ≥40 years, smoker: ≥20 pack-years). The duration of spirometry and its quality were evaluated according to the following acceptability criteria: 1) expiration ≥6 seconds or reaching a plateau; 2) good start with an early peak flow, curve peaked on top and not flat; 3) no artifacts; and 4) reproducibility criteria, ie, forced expiratory volume in 1 second and forced vital capacity differences between the two best spirometry curves ≤0.15 L. Quality of the spirograms was defined as optimal when all the criteria were met and acceptable when all the criteria were satisfied except the reproducibility criterion, otherwise, it was unacceptable. For the 152 patients included, the 142 assessable spirometries lasted for 15.2±5.9 minutes. Acceptability criteria 1-3, respectively, were satisfied for 90.1%, 89.4%, and 91.5% of patients and reproducibility criterion 4 for 56.3%. Quality was considered optimal for 58.5% of the curves and acceptable for 30.2%. The duration of spirometry renders it poorly compatible with the current primary-care practice in France other than for dedicated consultations. Moreover, the quality of spirometry needs to be improved.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 44 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United Kingdom 1 2%
Unknown 43 98%

Demographic breakdown

Readers by professional status Count As %
Researcher 13 30%
Student > Master 7 16%
Student > Doctoral Student 5 11%
Other 3 7%
Student > Bachelor 3 7%
Other 3 7%
Unknown 10 23%
Readers by discipline Count As %
Medicine and Dentistry 15 34%
Nursing and Health Professions 9 20%
Agricultural and Biological Sciences 2 5%
Economics, Econometrics and Finance 1 2%
Neuroscience 1 2%
Other 2 5%
Unknown 14 32%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 15 February 2016.
All research outputs
#20,655,488
of 25,373,627 outputs
Outputs from International Journal of Chronic Obstructive Pulmonary Disease
#2,078
of 2,577 outputs
Outputs of similar age
#300,609
of 406,420 outputs
Outputs of similar age from International Journal of Chronic Obstructive Pulmonary Disease
#57
of 65 outputs
Altmetric has tracked 25,373,627 research outputs across all sources so far. This one is in the 10th percentile – i.e., 10% of other outputs scored the same or lower than it.
So far Altmetric has tracked 2,577 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 6.5. This one is in the 6th percentile – i.e., 6% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 406,420 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 14th percentile – i.e., 14% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 65 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.