Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

Overview of attention for article published in Medical Devices : Evidence and Research, March 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Readers on

mendeley
22 Mendeley
Title
Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating
Published in
Medical Devices : Evidence and Research, March 2016
DOI 10.2147/mder.s102094
Pubmed ID
Authors

Noboru Saito, Yuhei Mori, Sayaka Uchiyama

Abstract

The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC), which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES) by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC) sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC) is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically significant conclusion.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 22 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 22 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 5 23%
Student > Master 4 18%
Student > Doctoral Student 3 14%
Student > Ph. D. Student 2 9%
Unspecified 1 5%
Other 2 9%
Unknown 5 23%
Readers by discipline Count As %
Engineering 5 23%
Chemistry 2 9%
Materials Science 2 9%
Medicine and Dentistry 2 9%
Immunology and Microbiology 1 5%
Other 6 27%
Unknown 4 18%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 18 March 2016.
All research outputs
#20,723,696
of 25,457,858 outputs
Outputs from Medical Devices : Evidence and Research
#235
of 314 outputs
Outputs of similar age
#231,416
of 312,788 outputs
Outputs of similar age from Medical Devices : Evidence and Research
#5
of 6 outputs
Altmetric has tracked 25,457,858 research outputs across all sources so far. This one is in the 10th percentile – i.e., 10% of other outputs scored the same or lower than it.
So far Altmetric has tracked 314 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 12.3. This one is in the 8th percentile – i.e., 8% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 312,788 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 13th percentile – i.e., 13% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 6 others from the same source and published within six weeks on either side of this one.